As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
THIS ITEM WAS FOUND DURING ROUTINE MAINTENANCE AT THE TIMCO OSC MAINTENANCE FACILITY. FLOORBEAM UPPER CAP AT BS 360, RBL 63 HAS DOUBLER DRILLED HOLES. REMOVED DAMAGES SECTION OF FLOORBEAM. FABRICATED REPAIR ANGLE IAW B727 SRM 53-10-8. INSTALLED REPAIR IAW B727 SRM 53-10-8 FIG 8. AIRCRAFT WAS RETURNED TO SERVICE. (M)