What was found
DURING A CPCP INSPECTION, IT WAS DISCOVERED THAT RIGHT ELEVATOR INTERIOR Z ANGLE IS CRACKED AT ELEVATOR STATION 25. ACCOMPLISHED ELEVATOR Z ANGLE REPLACEMENT AT RIGHT ELEVATOR STATION 25.0 IAW SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING A CPCP INSPECTION, IT WAS DISCOVERED THAT RIGHT ELEVATOR INTERIOR Z ANGLE IS CRACKED AT ELEVATOR STATION 25. ACCOMPLISHED ELEVATOR Z ANGLE REPLACEMENT AT RIGHT ELEVATOR STATION 25.0 IAW SRM.