What was found
DURING C-CHECK, FOUND MAIN CABIN FRAME BS 540 HAS DENT INTO THE RADIUS AT STRINGER 16 RT, FASI N/N 35744. CUT OUT DAMAGED AREA, FABRICATED SECTION OF FRAME MATERIAL USED 7075-T6 .063 P/O NR 991245 DIM 12 INCHES BY 3.5 INCHES, DOUBLER 7075-T6 .071 P/O NR 991208 DIM 12 INCH BY 5.5 INCH AND FILLER 2024-T3 .032 P/O NR 991813 DIM 2.5 INCH, INSTALLED IAW SRM 51-40-3. (M)