What was found
DURING C-CHECK, FOUND UPPER AND LOWER RUDDERS LEADING EDGES TEFLON ANTI-CHAFE PAINT WORN OUT, BOTH RUDDERS HAVE AREAS OF CHAFING. FOUND 6 AREAS ON LOWER RUDDER OUT OF LIMITS, FABRICATED 6 DOUBELRS, TWO 21.5 AND 14.25, TWO 15.25 BY 23.5, TWO 13.5 BY 15.5 ALL FROM 301 ONE QUARTER HARD AND INSTALLED IAW B727 SRM 55-40-3 FIG 1. UPPER RUDDER NO DAMAGE NOTED, REPAINTED IAW B727 MM 51-20-71. (M)