What was found
DURING C-CHECK INSPECTION FOUND STRINGER 15 LT CRACKED AT BS 720B PLUS 10. REF FASI N/R NR 61424, INSTALLED DOUBLER REPAIR PER B727 SRM 53-10-5 FIG 5. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK INSPECTION FOUND STRINGER 15 LT CRACKED AT BS 720B PLUS 10. REF FASI N/R NR 61424, INSTALLED DOUBLER REPAIR PER B727 SRM 53-10-5 FIG 5. (M)