What was found
DURING C-CHECK INSPECTION FOUND FUSELAGE FRAME DENTED IN RADIUS BS 480 ABOVE STRINGER 17 RT. REF FASI N/R NR 61830, CUT OUT DAMAGE AND INSTALLED 9 INCH BY 6 FT REPAIR DOUBLER PER B727 SRM 51-40-3 FIG 1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK INSPECTION FOUND FUSELAGE FRAME DENTED IN RADIUS BS 480 ABOVE STRINGER 17 RT. REF FASI N/R NR 61830, CUT OUT DAMAGE AND INSTALLED 9 INCH BY 6 FT REPAIR DOUBLER PER B727 SRM 51-40-3 FIG 1. (M)