What was found
DURING C-CHECK INSPECTION FOUND FUSELAGE FRAME DENTED IN RADIUS BS 700 ABOVE STR 17 RT. REF FASI N/R NR 61833, CUTOUT DAMAGE AND INSTALLED REPAIR DOUBLER 8 INCH BY 5.5 INCH PER B727 SRM 51-40-3 FIG 3. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK INSPECTION FOUND FUSELAGE FRAME DENTED IN RADIUS BS 700 ABOVE STR 17 RT. REF FASI N/R NR 61833, CUTOUT DAMAGE AND INSTALLED REPAIR DOUBLER 8 INCH BY 5.5 INCH PER B727 SRM 51-40-3 FIG 3. (M)