What was found
DURING C-CHECK INSPECTION FOUND NR 5 SLAT L/E LOWER TO OB END PREVIOUS REPAIR MISS MATCH. REF FASI NR 86609, REMOVED PREVIOUS REPAIR FROM NR 5 SLAT. INSTALLED DOUBLER REPAIR IAW SRM 57-50-3, FIG 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK INSPECTION FOUND NR 5 SLAT L/E LOWER TO OB END PREVIOUS REPAIR MISS MATCH. REF FASI NR 86609, REMOVED PREVIOUS REPAIR FROM NR 5 SLAT. INSTALLED DOUBLER REPAIR IAW SRM 57-50-3, FIG 1.