What was found
DURING C-CHECK INSPECTION FOUND MAIN CABIN FRAME AT BS 660 ABOVE STR17,16 RT, DENTED. REF FASI NR 86687, CUT OUT DAMAGED AREA DIM 1.0 X 2.25 AND 1.0 X 2.25. INSTALLED ANGLE REPAIR IAW SRM 51-40-3, FIG 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK INSPECTION FOUND MAIN CABIN FRAME AT BS 660 ABOVE STR17,16 RT, DENTED. REF FASI NR 86687, CUT OUT DAMAGED AREA DIM 1.0 X 2.25 AND 1.0 X 2.25. INSTALLED ANGLE REPAIR IAW SRM 51-40-3, FIG 1.