What was found
DURING CPC INSPECTION, THE FOLLOWING LEVEL 2 CORROSION ITEMS WERE NOTED: C53-100-01 - 2-24 END FITTING CORRODED AT BS 1183 BULKHEAD. REMOVED AND REPLACED END FITTING IAW B727 SRM 51-10-1 AND SRM 51-30-2. REF: OPER CONTROL NR 98ZZZX3038 THROUGH 98ZZZX3046. NOTE: THESE CPC ITEMS WERE FOUND DURING A PHASE-IN INSPECTION OF THIS AIRCRAFT PRIOR TO PUTTING IT ON THE KHA OPERATING CERTIFICATE. (X)