As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MAJOR REPAIR - DENT/GOUGE JUST AFT OF CARGO DOOR CUT OUT. AREA AFFECTED IS APPROXIMATELY 14 INCHES LONG BETWEEN FRAME 45 & 46 FROM F.S.15435 TO F.S. 15790 JUST BELOW CARGO FLOOR. MAINTENANCE REPAIRED AREA AT FRAMES 45 AND 46 FROM F.S.15435 TO F.S. 15790 I.A.W. EMB-120 SRM 53-00. REPAIR DIMENSIONS APPROXIMATELY 19 1/4 INCH X 9 INCH. MATERIAL 2024-T3 .O4O. RII INSPECTION COMPLIED WITH I.A.W. TASK CARD 8.2.1.