What was found
DURING SCHEDULED STRUCTURAL INSP, A FRAME WAS FOUND CRACKED AROUND 2 RIVETS AT APPROX FS 544.75 AT STRINGERS 1R AND 13R. TWO CRACKS TOTALING .625". MX MANUFACTURED DOUBLER AND REPAIRED AFFECTED AREA IAW EO 09-UE202-05. OUT OF .040 INCH, 2024 T3 AL ALCLAD. MS20470AD RIVETS. AC240B 1/2 SEALANT. PATCH APPROX 4.3" X 2.0". RII INSP COMPLIED WITH IAW TASKCARD 8.2.1.