As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING ROUTINE SCHEDULED MX, FUEL WAS FOUND LEAKING FROM A PREVIOUS REPAIR AT STRINGER 8 ON THE RT WING AT THE OTBD AFT CORNER NEAR PANEL 622EB. STRINGER IS CRACKED APPROX 2 INCHES. MX REPAIRED THE AFFECTED AREA AND PERFORMED THE REQUIRED RII INSPECTIONS IAW EO 09-120-57-006. MATERIALS UTLIZED ARE LISTED IN THE EO.