What was found
MAJOR REPAIR - DURING A SCHEDULED ROUNTINE INSPECTION A .75" CRACK WAS FOUND ON THE FRAME FLANGE AT F.S. 273.25 AND STRINGER 2R CUTOUT OUTBOARD OF STRINGER 2R, AND CRACKED .7" ON THE FRAME FLANGE INBOARD OF STRINGER 2R, AND A CRACK .7" I/B OF STRINGER 10R. MAINTENANCE REPAIRED THE AFFECTED AREA AND PERFORMED ALL REQUIRED RII INSPECTIONS IAW EO 10-1900-53-036. MATERIALS UTILIZED ARE INCLUDED IN THE ENGINEERING ORDER.