What was found
DURING A SCHEDULED ROUTINE INSPECTION, FOUND LT UPPER FWD PRESSURE BULKHEAD AT FS 84.0 CRACKED AT FASTENER HOLE ALONG BOTTOM EDGE OF PRESSURE BULKHEAD, 5.75" FROM THE LT OTBD PRESS BULKHEAD EDGE, CRACK RADIATES UPWARD FROM FASTENER HOLE, .1875" IN LENGTH. REPAIRED THE AFFECTED AREA AND PERFORMED ALL REQUIRED RII INSPECTIONS IAW EO 12-1900-53-043. MATERIALS UTILIZED ARE INCLUDED IN THE EO. MAJOR REPAIR.