What was found
CABIN OXYGEN CONTROL PULLED DUE TO CABIN ALTITUDE EXCEEDING 10000FT AND CABIN ALTITUDE INCREASING AT 4000FT IAW MIN CREW TRIED TO RESET SYS, ADJ CABIN HEAT, RAN CHECKLIST, DEPLOYED MASKS AND DESCENDED. AT 5000FT ALTITUDE, ACFT BEGAN TO PRESSURIZE. OUTFLOW VALVE REMOVED. R & R CABIN PRESSURE CONTROLLER IAW MM 21-30-07 A (A B) 21-30-00,