What was found
DURING A SCHEDULED INSPECTION MX FOUND 2 CRACKS IN THE RT SIDE OF FS 107 & STRINGER 8R, FRAME ANGLE & LONGERON, FRAME CRACKED AT UPPER END OF FRAME IN BEND RADIUS. LONGERON CRACKED FROM LOWER EDGE TO LONGERON UPWARD THROUGH BEND RADIUS, 1.5 INCHES IN LENGTH. REPAIRED THE AFFECTED AREA AND PERFORMED ALL REQUIRED RII INSPECTIONS IAW EO 14-1900-53-008.