What was found
DURING A SCHEDULED INSPECTION MX FOUND CORROSION AT FS 288.000 ON THE FRAME WHERE THE STRINGERS 16, 15R, 15L, 14R, & 14L ATTACHED, AREA OF 3 INCHES WIDE BY 2 INCHES. REPAIRED THE AFFECTED AREA AND PERFORMED ALL REQUIRED RII INSPECTIONS IAW EO 14-1900-53-014.