What was found
DURING A SCHEDULED INSPECTION MAINTENANCE FOUND CORROSION ON THE FUSELAGE FRAME AT FS 198.25 BETWEEN STRINGERS 15L & 14L, UPPER SURFACE, AREA CORRODED 2.25 INCHES BY .75 INCHES. DEEPEST PITTED AREA IS APPROX .03 INCHES ALONG LE, DEEP PITTED SPOT TOWARD STRINGER 14L IS APPROX .023 INCHES, THICKNESS AT FRAME FLANGE .10 INCHES. REPAIRED IAW EO 14-1900-53-031.