What was found
THE HAND MIC SMELLED HOT & STARTED SENDING STATIC TO THE INTERCOM SYS. PLUGGED INTO INTO FIRST OFFICER`S JACK. REPLACED PC BOARD PN ON & OFF 130-340097-1 IN THE AUDIO CONTROL PANEL, SN OFF UNKNOWN, SN ON 504-8-95. WORK ACCOMPLISHED IAW AIM 10-24-01. REPLACED HAND MIC, PN ON & OFF 602-3376, SN OFF 12309, SN ON 12777. OPERATIONAL CHECK GOOD.