What was found
MAJOR REPAIR, DURING A SCHEDULED INSPECTION, FOUND 2 CRACKS AT CANT BULKHEAD, AT FS 588.10 AT JUNCTION WITH STRINGER 8R, CANT BULKHEAD AT FIRST FASTENER TOP SIDE AT STRINGER 8R & AT FIRST FASTENER BELOW STRINGER 8R, BOTTOM CRACK RADIATES UPWARD & DOWNWARD FROM FASTENER, 1.05" IN TOTAL LENGTH. REPAIRED IAW EO 15-1900-53-018.