What was found
PILOTS REPORTED THAT THE BRAKES REQUIRE EXCESSIVE PRESSURE TO ACTIVATE. STOPPING POWER IS VERY LIMITED. MAINTENANCE R & R THE NR 2 BRAKE AND NR 4 BRAKE IAW MM 32-41-05, OPS CHECKED GOOD. R & R THE NR 1 BRAKE ASSY IAW MM 32-41-05, OPS CHECKED GOOD. R & R THE NR 3 BRAKE ASSY IAW MM 32-41-05, OPS CHECKED GOOD.