SDR GLBA97176

Service difficulty report · Switch · Beech 1900D

Difficulty date
September 26, 1997
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N100UX
Make and model
Beech 1900D
Aircraft serial
UE100
Part
Switch
Condition
Ouf Of Adjust
Location
Te Flaps
Stage of operation
CL
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FRM - FLAPS SELECTED AT 17 DEGREES FOR TAKEOFF. FLAPS WENT TO 35 DEGREES WITHOUT BEING SELECTED. RETURN TO GATE. RIGGED FLAP LIMIT SWITCH. (M)

More about the Beech 1900D