What was found
AUTOTHROTTLES OFF AND EQUAL ERP, THE LEFT EPR VALUE DECREASES .11 AND THE RIGHT EPR INITIALLY INCREASES .02 THEN DECREASES .03 LEAVING AN EPR SPLIT OF .08 N1 AND N2 BOTH CHANGE BY APPROXIMATELY EQUAL AMOUNT. WITH AUTOTHROTTLES ON AND SYNC ON THE EPR SPLIT IS .16 (N1 AND N2 ARE MATCHED) WITH ENGINE ANTI-ICE ON FOR ABOVE CONDITIONS. CHANGED IN EPR NOTED ABOVE OCCUR WHEN ENGINE ANIT-ICE IS TURNED ON. CRUISE AUTOTHROTTLES/SYNC AND ENGINE ANTI-ICE ON THE RIGHT EPR IS AT MAXIMUM/BOTH N1'S MATCHED AUTHOTHROTTLES UNABLE TO MAINTAIN .76M (FL350) UNLESS AUTOTHROTTLES ARE TURNED OFF AND LEFT THROTTLE ADVANCED. FOUND HOLE IN NR 2 NOSE BULLET REMOVED AND REPLACED IAW MM CH 71-00-00. (M)