What was found
FOUND FLOOR SUPPORT, LEFT AFT LAVATORY AREA, CORRODED TWO PLACES, FS 1338L, APPROX BL24L AND BL60. REMOVED FLOOR SUPPORT IAW MD80 SRM 51-30-2 AND 51-30-5. FABRICATED ANGLE SUPPORT AND INSTALLED PER MD80 SRM 51-30-2 AND 51-30-5. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.