As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FTW - FORWARD PAX DOOR L1 HAS LEAK AT STATION Y 190 Z34.5 BETWEEN LL BEAM NR 5 AND LL BEAM NR 4. REMOVED CRACKED RIB IAW MD80 SRM 51-30. FOUND BEAM IAW MD80 SRM 52-05. DURING REMOVAL FOUND TEE ANGLE CRACKED. FORMED 'T' ANGLE IAW MD80 SRM 52-05. DRILLED UP AND LOCATED RIB. INSTALLED RIB. INSTALLED 'T' ANGLE PER MD80 SRM 51-30-2. (M)