What was found
FTW - FOUND FLOOR SUPPORT CORRODED AT STA Y=200 FROM -X47 INCHES TO -X=56 INCHES. REMOVED SUPPORT ANGLE. FORMED NEW FLOOR SUPPORT ANGLE IAW DC9 SRM 53-11-1. INSTALLED NEW SUPPORT ANGLE IAW DC9 SRM 53-11-1 OR 51-30-8. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FTW - FOUND FLOOR SUPPORT CORRODED AT STA Y=200 FROM -X47 INCHES TO -X=56 INCHES. REMOVED SUPPORT ANGLE. FORMED NEW FLOOR SUPPORT ANGLE IAW DC9 SRM 53-11-1. INSTALLED NEW SUPPORT ANGLE IAW DC9 SRM 53-11-1 OR 51-30-8. (M)