What was found
FTW - FOUND NR 3 RIGHT SLAT OUTBOARD LOWER CHORD ANGLE CHAFFED MORE THAN 50 PERCENT OF MATERIAL THICKNESS. FORMED NEW CHORD ANGLE. INSTALLED FASTENERS IAW DC9 SRM 51-30-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FTW - FOUND NR 3 RIGHT SLAT OUTBOARD LOWER CHORD ANGLE CHAFFED MORE THAN 50 PERCENT OF MATERIAL THICKNESS. FORMED NEW CHORD ANGLE. INSTALLED FASTENERS IAW DC9 SRM 51-30-2. (M)