What was found
FTW - E/E BAY INTERCOSTAL ABOVE 28L STRINGER HAS CORRODED. FABRICATED NEW INTERCOSTAL AND HEAT TREATED. INSTALLED INTERCOSTAL IAW DC9 SRM 51-30-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FTW - E/E BAY INTERCOSTAL ABOVE 28L STRINGER HAS CORRODED. FABRICATED NEW INTERCOSTAL AND HEAT TREATED. INSTALLED INTERCOSTAL IAW DC9 SRM 51-30-2. (M)