FTW - FOUND FLOOR SUPPORT CORRODED AT STATION Y=200 FROM -24 INCH TO -X43, FOUND AFTER G-1 REMOVED DUE A CORROSION BEYOND LIMITS AT FLOOR SUPPORT. DRILLED AND LOCATED FLOOR SUPPORT. INSTALLED FLOOR SUPPORT IAW DC9 SRM 51-30-5. (M)