What was found
FTW - FOUND CABIN FLOORBOARD LEFT, OUTBOARD STATION 389-465, LOWER SIDE RETAINER BROKEN IN HALF (FIBERGLASS) SURFACE CORROSION AND BARE METAL AREAS ON SKIN. AREA FOUND OUT OF LIMITS. FABRICATED NEW FLOORBOARD PER DC9 SRM 51-10-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FTW - FOUND CABIN FLOORBOARD LEFT, OUTBOARD STATION 389-465, LOWER SIDE RETAINER BROKEN IN HALF (FIBERGLASS) SURFACE CORROSION AND BARE METAL AREAS ON SKIN. AREA FOUND OUT OF LIMITS. FABRICATED NEW FLOORBOARD PER DC9 SRM 51-10-2. (M)