What was found
FTW - FOUND FORWARD CARGO DOOR CHAFING SEVERAL SPOTS OUTER. LOWER AFT AT OUTER EDGE FOUND TO BE OUT OF LIMITS. FABRICATED, DRILLED AND LOCATED DOUBLER. INSTALLED DOUBLER AND FILLER PER MD80 SRM 52-05. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FTW - FOUND FORWARD CARGO DOOR CHAFING SEVERAL SPOTS OUTER. LOWER AFT AT OUTER EDGE FOUND TO BE OUT OF LIMITS. FABRICATED, DRILLED AND LOCATED DOUBLER. INSTALLED DOUBLER AND FILLER PER MD80 SRM 52-05. (M)