What was found
FTW - FORWARD ENTRY AREA, FLOORBOARD FROM STATION 200-260 X23 TO X44 HAS MISSING INSERTS, BROKEN INSERTS, PUNCTURES AND CORNERS CRACKED. FABRICATED NEW FLOORBOARD. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FTW - FORWARD ENTRY AREA, FLOORBOARD FROM STATION 200-260 X23 TO X44 HAS MISSING INSERTS, BROKEN INSERTS, PUNCTURES AND CORNERS CRACKED. FABRICATED NEW FLOORBOARD. (M)