What was found
FTW - FOUND E/E COMPARTMENT LONGERON 25 LEFT STATION 160 HAS CORROSION. REMOVED CORROSION AT LONGERON. LOCATED AND DRILLED LONGERON SECTION REPAIR AND SPLICE. INSTALLED LONGERON SECTION REPAIR AND SPLICE. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FTW - FOUND E/E COMPARTMENT LONGERON 25 LEFT STATION 160 HAS CORROSION. REMOVED CORROSION AT LONGERON. LOCATED AND DRILLED LONGERON SECTION REPAIR AND SPLICE. INSTALLED LONGERON SECTION REPAIR AND SPLICE. (M)