What was found
FTW - FOUND OVERWING EMERGENCY EXITS ESCAPE LINES FOUR EACH, HOOKS CORRODED, SURFACE CORROSION. UPON CORROSION REMOVAL ESCAPE ROPES STARTED FRAYING AND STILL HOOK CORRODED UNDER ROPES, 4 EACH. REMOVED RIGHT FORWARD ESCAPE LINE. REMOVED LEFT FORWARD ESCAPE LINE. REMOVED RIGHT AFT E-LINE. REMOVED LEFT AFT E-LINE. INSTALLED RIGHT AFT ESCAPE LINE. INSTALLED LEFT FORWARD ESCAPE LINE. INSTALLED LEFT AFT ESCAPE LINE, INSTALLED RIGHT FORWARD ESCAPE LINE. (M)