What was found
FTW - FOUND CABIN FLOORBOARD STATION 1155-1250 X46 TO X56 STIFFENER CHANNEL CRACKING, REPAIR DEBONDING, PHENOLIC BACKSTRIPS BROKEN AND FASTENER HOLE ENLARGED. REPAIRED CABIN FLOOR PANEL STATION 1155-1250. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FTW - FOUND CABIN FLOORBOARD STATION 1155-1250 X46 TO X56 STIFFENER CHANNEL CRACKING, REPAIR DEBONDING, PHENOLIC BACKSTRIPS BROKEN AND FASTENER HOLE ENLARGED. REPAIRED CABIN FLOOR PANEL STATION 1155-1250. (M)