What was found
FTW - AFT PIT STATION 1155-1212 L28R, REPAIR STRAP ON DOOR JAMB BEAM HAS AREAS OF CORROSION ENTIRE LENGTH OF REPAIR. AFT PIT STATION 1155-1212 L28R EVIDENCE OF CORROSION BETWEEN SKIN/DOUBLER AND LOWER FLANGE OF DOOR JAMB BEAM. AFT CARGO FLOOR SUPPORT STATION 1155 HAS CORROSION AND DOUBLE DRILLED HOLES. REMOVED REPAIR STRAP. AFTER REMOVING STRAP AND REPAIR DOUBLER FOUND CORROSION ON DOOR BEAM TO BE OUT OF LIMITS. REMOVED DOOR JAMB CORNER ANGLE STATION 1155. CORNER ANGLE HAS CORROSION OUT OF LIMITS STATION 1155. REMOVED AFT CARGO DOOR FLOORBEAM FROM STATION 1117-1250 L28R. LOCATED AND DRILLED NEW FLOORBEAM. INSTALLED NEW BEAM. (M)