What was found
FTW - AFT PIT LOWER DOOR CUT OUT HAS CORROSION AT OUTBOARD BEAM SURFACE ANGLE ALONG EDGE BEAM. BEAM OUT OF LIMITS AT STATION 1188 AND STATION 1171. FABRICATED DOUBLER AND SPACER. INSTALLED DOUBLER AND SPACER. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FTW - AFT PIT LOWER DOOR CUT OUT HAS CORROSION AT OUTBOARD BEAM SURFACE ANGLE ALONG EDGE BEAM. BEAM OUT OF LIMITS AT STATION 1188 AND STATION 1171. FABRICATED DOUBLER AND SPACER. INSTALLED DOUBLER AND SPACER. (M)