What was found
FTW - FORWARD LIGHT CORROSION BARE METAL AT LONGERON 29L STATION 503, 484. MATERIAL LOSS OUT OF LIMITS. FABRICATRED -3 STRAP PER DWG NO 53100228-1 9SH 2 OF 2) EA 5310-0228. INSTALLED -3 STRAP. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FTW - FORWARD LIGHT CORROSION BARE METAL AT LONGERON 29L STATION 503, 484. MATERIAL LOSS OUT OF LIMITS. FABRICATRED -3 STRAP PER DWG NO 53100228-1 9SH 2 OF 2) EA 5310-0228. INSTALLED -3 STRAP. (M)