What was found
FTW - MID PIT FLOORBEAM HAS CHAFING/DAMAGE STATION 655. MATERIAL LOSS OUT OF LIMITS. FORMED ANGLES. INSTALLED ANGLES. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FTW - MID PIT FLOORBEAM HAS CHAFING/DAMAGE STATION 655. MATERIAL LOSS OUT OF LIMITS. FORMED ANGLES. INSTALLED ANGLES. (M)