What was found
FTW - FOUND AFT CABIN STATION 1309 CORROSION ON BEAM ATTACH FITTING RBL 60. REMOVED ATTACH FITTING. UPON REMOVAL OF ATTACH FITTING FOUND CORROSION ON WEB. REMOVED CORRODED WEB. LOCATED, DRILLED AND DEBURRED REPAIR WEB. INSTALLED REPAIR WEB. LOCATED, DRILLED AND DEBURRED ATTACH FITTING. INSTALLED ATTACH FITTING.