What was found
FTW - FOUND 4 HOLES IN FLOOR WEBBING, LBL 18 STATION 200-218. REMOVED THE DAMAGED FLOOR WEBBING AT LBL 18, STATION 200-218. FABRICATED PRESSURE FLOOR FILLER ROOM AND DOUBLERS. INSTALLED WEB FILLER AND TWO DOUBLERS. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FTW - FOUND 4 HOLES IN FLOOR WEBBING, LBL 18 STATION 200-218. REMOVED THE DAMAGED FLOOR WEBBING AT LBL 18, STATION 200-218. FABRICATED PRESSURE FLOOR FILLER ROOM AND DOUBLERS. INSTALLED WEB FILLER AND TWO DOUBLERS. (M)