What was found
FTW - FOUND FORWARD CARGO PIT CORROSION, BARE METAL AND CRACKED DAMAGED SEALANT ALL ALONG INBOARD FRAME AT DOOR JAMB PANEL FROM 3 O'CLOCK TO 9 O'CLOCK POSITION. FOUND CORROSION OUT OF LIMITS. CUT OUT FORWARD CARGO DOOR JAMB PANEL FROM 5 O'CLOCK TO 7 O'CLOCK FS 370-427. LOCATED AND DRILLED NEW FORWARD CARGO DOOR JAMB PANEL FROM 5 O'CLOCK TO 7 O'CLOCK FS 370-427. INSTALLED WEB STATION 364-423 AT FORWARD CARGO DOOR. (M)