As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FTW - FOUND CORRODED WEB LONGERON 18L BETWEEN STATION 1079 AND 1098 UPPER CEILING AFT CARGO PIT. REMOVED DAMAGED WEB FROM STATION 1055 TO 1098. FOUND MORE CORROSION AT STATION 1022. OBTAINED MEMBRANE (WEB) FROM STOCK ROOM, LOCATED AND DRILLED MEMBRANE. INSTALLED NEW WEB. (M)