What was found
FTW - FOUND FLOOR WEB CORRODED AT BOTTOM OF L2 DOOR STATION 1136-1174 (2) Z-ANGLE BRACKETS CORRODED TWO EACH. CUT OUT FLOOR WEB. FABRICATED FILLER AND DOUBLER. INSTALLED DOUBLER REPAIR AND FILLER. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FTW - FOUND FLOOR WEB CORRODED AT BOTTOM OF L2 DOOR STATION 1136-1174 (2) Z-ANGLE BRACKETS CORRODED TWO EACH. CUT OUT FLOOR WEB. FABRICATED FILLER AND DOUBLER. INSTALLED DOUBLER REPAIR AND FILLER. (M)