FTW - FOUND FORWARD ENTRY AREA, FLOOR SUPPORT STATION 160 TO 200 RBL 48 CORRODED. FLOOR GALLEY MOUNT CORRODED AT STATION 160 RBL 48. REMOVED FLOOR SUPPORT. FABRICATED NEW FLOOR SUPPORT. INSTALLED FLOOR SUPPORT. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FTW - FOUND FORWARD ENTRY AREA, FLOOR SUPPORT STATION 160 TO 200 RBL 48 CORRODED. FLOOR GALLEY MOUNT CORRODED AT STATION 160 RBL 48. REMOVED FLOOR SUPPORT. FABRICATED NEW FLOOR SUPPORT. INSTALLED FLOOR SUPPORT. (M)