As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
GTIA - FOUND CABIN STATION 148 RBL 45 - RBL 52 FLOORBEAM CORRODED AND STATION 146 RBL 52 FLOOR SUPPORT CORRODED. REMOVED CORROSION AT STATION 146 RBL 52. MATERIAL LOSS FOUND WITHIN LIMITS. FABRICATED FLOORBEAM AT STATION 148 RBL 45-52. INSTALLED NEW FLOOR SUPPORT. (M)