SDR GTIA031039

Service difficulty report · Controller · Doug DC982

Difficulty date
December 11, 2003
Submitted
January 13, 2004
Operation
Air carrier
Aircraft
N801NK
Make and model
Doug DC982
Aircraft serial
48048
Part
Controller
Part number
60714622
Condition
Failed
Location
Cabin Temp
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIRCRAFT WOULDN'T HOLD CABIN PRESSURE. CABIN WARNING VOICE FLOW LIGHT ON. LEFT VALVE TEMP FULL HOT (AUTO) REDUCED TEMP BOTH PACKS LEFT PACK ON 30 SEC FLOW LIGHT ON MASK DROPPED. MANUAL MODE ON OUTFLOW VALVE. PERFORMED TEST ON TEMP CONTROLLER SYSTEM WITH TEST BOX. CONFIRMED LEFT CONTROLLER TO BE BAD. REMVOED AND REPLACED TEMP CONTROLLER. OPS CHECKS GOOD. PERFORMED LEAK CHECK OF DUCTING AND PRESSURIZATION CHECK. FOUND NO OTHER DEFECTS NOTED AT THIS TIME. (M)