What was found
FTW - FOUND CORROSION ON JAMB BEAM BETWEEN FS 636-693 AROUND RIVETS AND DRILLED OFF SCREWS. FABRICATED 15 DOUBLER AND 9 SPACER. INSTALLED DOUBLER AND SPACER. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FTW - FOUND CORROSION ON JAMB BEAM BETWEEN FS 636-693 AROUND RIVETS AND DRILLED OFF SCREWS. FABRICATED 15 DOUBLER AND 9 SPACER. INSTALLED DOUBLER AND SPACER. (M)