What was found
FTW - FOUND FORWARD CABIN STATION 120 RBL 28, 34 INCHES, 38 INCHES, 45 INCHES HAS PUNCTURE/DAMAGED ON DIAPHRAM WEB PANEL. REMOVED DAMAGED AREAS. FABRICATED, LOCATED, AND DRILLED REPAIR DOUBLER AND FLOOR SUPPORT. FURTHER FOUND DAMAGED AT SUB FLOOR WEB STATION 120 RBL 12 INCHES. REMOVED DAMAGED WEB. FABRICATED REPAIR DOUBLER. INSTALLED REPAIR DOUBLER AT FLOOR WEB STATION 120 RBL 12 INCHES. INSTALLED DOUBLER AND FLOORBOARD SUPPORT AT STATION 120 RBL 28 TO 45. (M)